Airvo™ 2 nasal high flow system

$3,998.00 $2,998.50

In StockPre-orderOut of stock

A humidified high-flow system designed to treat patients across the care continuum.

The AIRVO 2 is a humidifier with integrated flow generator that delivers high flow warmed and humidified respiratory gases to spontaneously breathing patients though a variety of patient interfaces.

The AIRVO 2is for the treatment of spontaneously breathing patients who would benefit from receiving high flow warmed and humidified respiratory gasses. This includes patients who have had upper airways bypassed. The flow may be from 2-60L/min depending on the patient interface. 

Proven
Optiflow high flow therapy has been proven to be an effective therapy for:
acute hypoxemia respiratory failure
post-extubation respiratory support
post-operative respiratory support
immunocompromised patients with acute hypoxemia
patients with COPD.

Broad flow range
A broad flow range (2 to 60 L/min) takes your patients from the most acute environments (ICU and ED) to the home.

Transportable
A compact system with a built-in flow generator means there’s no need for a noisy, heavy air compressor to transport the Airvo 2. Add a suitable UPS, and you’re ready to go.

Variety of interfaces
A variety of interfaces have been designed with Optiflow High Flow Therapy in mind.

1. Controlled oxygen
Add and titrate oxygen separately from the flow rate.
From .21 (room air) to 1.0.
Onscreen FiO2 display.
2. 93% less condensate*
AirSpiral™ heated breathing tube with integrated dual-spiral heated wires and temperature sensor.
No separate temperature probes or adapters are required.
* When compared with the 900PT501 Airvo tube in internal Fisher & Paykel Healthcare testing.
3. Adjustable temperature
Three temperature settings (37, 34, 31 °C) help achieve comfort and compliance.
4. Transportable
Mobile pole, oxygen bottle holders, and transport kit designed for a UPS.

Includes:
HC360 chamber and heated breathing tube.

Dimensions 295 mm x 170 mm x 175 mm (11.6" x 6.7" x 6.9")
Weight 4.8 lb - unit only; 7.5 lb packaged
Humidity Output Complies with ISO 8185:2007 standard
Flow Settings 10 to 60 L/min (increments 5 L/min) - default
Flow Settings 2 to 25 L/min (increments 1 L/min) - junior mode
Patient Interfaces F&P Optiflow+ nasal cannulas
Humidity performance

>35 mg/L at 37°C target
>12 mg/L at 34°C target
>12 mg/L at 31°C target

Warm up time
10 minutes to 31°C (88 °F)
30 minutes to 37°C (98.6 “F)
Using a MR290 chamber with of 35 L/min an
starting temperature 23 + 2 °C
Sound pressure level
Alarms exceed 45dbA @ 1m
Auditory alarm Pressure
115 seconds
Expected service life 5 years
Target temperature settings 37, 34, 31 °C
Maximum temperature of delivered gas 43 °C (109 °F)
Maximum surface temperature of applied parts 44 °C (111 °F)
Flow range (default) 10-60 L/min
Maximum oxygen input 60L/min
Oxygen analyzer accuracy 

< + 4 % (within the range of 25-95% O2)
Operating conditions: 18-28 °C (64-82 “F), 30-7-% RH

Altitude

0 - 2000 m (6000 ft)

Mode of operation

Continuous operation

 

 [USER MANUAL]

Out of stock

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Browse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order Note Edit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

Coupon code will work on checkout page